NSN 1660-00-187-1386
Part Details | LIQUID OXYGEN CONVERTER
1660-00-187-1386 A unit consisting of a jacketed container, with or without a heat source, used to convert liquid oxygen into gasous breathing oxygen. See also CONVERTER, LIQUID OXYGEN PUMPING METHOD.
Alternate Parts: 8148650, 29073D2, MILC19803, MIL-C-19803, 1660-00-187-1386, 00-187-1386, 1660001871386, 001871386
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
16 | FEB 19, 1971 | 00-187-1386 | 12942 ( CONVERTER, LIQUID OXYGEN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 1660-00-187-1386
Part Number | Cage Code | Manufacturer |
---|---|---|
8148650 | 98748 | AIR FORCE UNITED STATES DEPARTMENTOF THE |
29073D2 | 99251 | CARLETON LIFE SUPPORT SYSTEMS INC.DBA COBHAM MISSION SYSTEM |
MIL-C-19803 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 1660-00-187-1386
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | CAPACITY 10 LITERS LIQUID OXYGEN,SUPPLY PRESSURE 55 TO 90 PSIG,OPERATING TEMPERATURE M54 DEG C TO P127 DEG C,NORMAL OPERATING PRESSURE 75 PSIG |
REFERENCE DATA AND LITERATURE | T.O. 15X2-6-4-34 |