NSN 4140-00-073-9866

Part Details | CENTRIFUGAL FAN

4140-00-073-9866 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 753039, 4140-00-073-9866, 00-073-9866, 4140000739866, 000739866

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JAN 01, 196100-073-986604254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, INVERTED, RECTANGULAR OUTLET

Cross Reference | NSN 4140-00-073-9866
Part Number Cage Code Manufacturer
75303956232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
Technical Data | NSN 4140-00-073-9866
Characteristic Specifications
STYLE DESIGNATOR FIXED, INVERTED, RECTANGULAR OUTLET
WIDTH6.187 INCHES MINIMUM AND 6.437 INCHES MAXIMUM
LENGTH8.438 INCHES NOMINAL
OUTLET INSIDE WIDTH2.281 INCHES NOMINAL
OUTLET INSIDE HEIGHT3.094 INCHES NOMINAL
HEIGHT9.641 INCHES NOMINAL
QUANTITY1
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
ELECTRICAL CONNECTION TYPE WIRE LEAD
PRIME MOVER POWER RATING0.722 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPM3200.0
VOLTAGE IN VOLTS AND CURRENT TYPE400.0 AC
PHASE THREE
AIR FLOW RATE285.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
ENVIRONMENTAL PROTECTION EXPLOSION PROOF
STAGE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
OUTLET LOCATION TOP
DISCHARGE DIRECTION VERTICAL UP
FEATURES PROVIDED NONSPARKING
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY NAVORD OD 41152