NSN 4140-00-215-8558

Part Details | TUBEAXIAL FAN

4140-00-215-8558 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.

Alternate Parts: 020191, CL3T2, CL3T-2, CLE3T2, OA254AP221TB,, OA254AP-22-1TB,, CL3T2, CL3T-2, CL3T, TC.N.GN, 363A010H10, CL3T2, 4140-00-215-8558, 00-215-8558, 4140002158558, 002158558

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41MAY 04, 197300-215-855804244 ( FAN, TUBEAXIAL )
REFERENCE DRAWINGS & PICTURES

FIXED

Cross Reference | NSN 4140-00-215-8558
Part Number Cage Code Manufacturer
0201915Y921COMAIR ROTRON INCSUB OF KL INDUSTRIES INC
CL3T-25Y921COMAIR ROTRON INCSUB OF KL INDUSTRIES INC
CLE3T25Y921COMAIR ROTRON INCSUB OF KL INDUSTRIES INC
OA254AP-22-1TB,1VEL5KNIGHT ELECTRONICS INCDBA ORION FANS
CL3T-282877ROTRON INCORPORATEDDBA AMETEK ROTRON
CL3T82877ROTRON INCORPORATEDDBA AMETEK ROTRON
TC.N.GNS5844SUNONWEALTH ELECTRIC MACHINEINDUSTRY CO. LTD
363A010H1065054WESTINGHOUSE ELECTRIC CORPPOWER GENERATION-GENERATOR DIV
CL3T2D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
Technical Data | NSN 4140-00-215-8558
Characteristic Specifications
STYLE DESIGNATOR FIXED
LENGTH3.500 INCHES NOMINAL
HOUSING INSIDE DIAMETER9.063 INCHES MINIMUM AND 9.167 INCHES MAXIMUM
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-30.0 DEG FAHRENHEIT AND 60.0 DEG FAHRENHEIT
ELECTRICAL CONNECTION TYPE TERMINAL
PRIME MOVER POWER RATING0.082 HORSEPOWER
OPERATING SPEED AT RATED CAPACITY IN RPMB1400.0$$B1650.0
VOLTAGE IN VOLTS AND CURRENT TYPEC220.0$C230.0
PHASE SINGLE
FREQUENCY IN HERTZB50.0$$B60.0
AIR FLOW RATE455.0 CUBIC FEET PER MINUTE MINIMUM AND 550.0 CUBIC FEET PER MINUTE MAXIMUM
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.0 INCHES OF WATER
FLOW DIRECTION INWARD
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE