NSN 4140-00-720-1368
Part Details | VENTILATING FAN
4140-00-720-1368 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.
Alternate Parts: NB3K13F1, NB3-K13F-1, 5642501, 564250-1, 5642501, 564250-1, A2263202, A2263-202, A22063202, A22063-202, 4140-00-720-1368, 00-720-1368, 4140007201368, 007201368
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JAN 01, 1963 | 00-720-1368 | 04262 ( FAN, VENTILATING ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-720-1368
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| NB3-K13F-1 | 02598 | AEROFLEX LABORATORIES INCROTATING COMPONENTS DIV |
| 564250-1 | 77068 | ALLIED-SIGNAL INCDBA ALLIED-SIGNAL AEROSPACE CO |
| 564250-1 | 59364 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
| A2263-202 | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
| A22063-202 | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
Technical Data | NSN 4140-00-720-1368
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 4.000 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 4.000 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | PARTIALLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | WIRE LEAD |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 6200.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | C115.0$C200.0 |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 150.0 CUBIC FEET PER MINUTE MAXIMUM |
| FLOW DIRECTION | INWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
| FEATURES PROVIDED | SAFETY IMPELLER GUARD |