NSN 4140-00-903-3965
Part Details | TUBEAXIAL FAN
4140-00-903-3965 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: SC445000031, SC4450-0003-1, 024109, PROPIMAX2414ZS, PROPIMAX2-414ZS, PROPIMAX2414ZH, PROPIMAX2-414ZH, SMC379983, SM-C-379983, 4140-00-903-3965, 00-903-3965, 4140009033965, 009033965
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | JAN 01, 1960 | 00-903-3965 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-903-3965
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| SC4450-0003-1 | 12115 | DRS ICAS, LLC |
| 024109 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| PROPIMAX2-414ZS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| PROPIMAX2-414ZH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| SM-C-379983 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 4140-00-903-3965
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 1.250 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 3.064 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -55.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| PRIME MOVER POWER RATING | 0.033 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 16500.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 96.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| ENVIRONMENTAL PROTECTION | WEATHERPROOF |
| FLOW DIRECTION | INWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 RIM |