NSN 4140-00-930-2605
Part Details | VANEAXIAL FAN
4140-00-930-2605 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 020457, A019472, A0-19472, AX2T208ACN817NH, AXIMAX2817NS, AXIMAX2-817NS, AXIMAX2817NH, AXIMAX2-817NH, 10175267, 4140-00-930-2605, 00-930-2605, 4140009302605, 009302605
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | MAY 06, 1966 | 00-930-2605 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-00-930-2605
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 020457 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| A0-19472 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| AX2T208ACN817NH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| AXIMAX2-817NS | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| AXIMAX2-817NH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| 10175267 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 4140-00-930-2605
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 1.469 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 1.891 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | 54.0 DEG CELSIUS AND 125.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL |
| PRIME MOVER POWER RATING | 0.053 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 19600.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 208.0 AC |
| PHASE | SINGLE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 50.0 CUBIC FEET PER MINUTE MINIMUM |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| STAGE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 RIM |
| ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF |
| FEATURES PROVIDED | NONSPARKING |