NSN 4140-01-046-6583
Part Details | TUBEAXIAL FAN
4140-01-046-6583 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 8651601, 865160-1, 8651600001, 865160-0001, 026746, PROPIMAX3B748WH, PROPIMAX3B-748WH, 4140-01-046-6583, 01-046-6583, 4140010466583, 010466583
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | AUG 20, 1977 | 01-046-6583 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-046-6583
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 865160-1 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATIONSYSTEMS DIVISION |
| 865160-0001 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATIONSYSTEMS DIVISION |
| 026746 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| PROPIMAX3B-748WH | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-046-6583
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| DIAMETER | 3.405 INCHES NOMINAL |
| LENGTH | 2.015 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 3.562 INCHES NOMINAL |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | THREE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -54.0 DEG CELSIUS AND 100.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| PRIME MOVER POWER RATING | 0.044 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 7500.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 127.000 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF |
| FLOW DIRECTION | OUTWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP RING |