NSN 4140-01-071-2977
Part Details | CIRCULATING FAN
4140-01-071-2977 A nonpositive displacement mechanical device having an axial fan impeller with or without a protective enclosure. It is designed to circulate air under free-airflow conditions, and may be equipped with a baffle(s) to deflect the air radially. It may be suspended from the ceiling, attached to the wall, or stand on a horizontal surface.
Alternate Parts: A7U6F1, A7U6F-1, MFPS5501R272W, MF-PS5501-R-272W, 7294081, 729408-1, 021449000, 021449, MFPS5501R272WF, MF-PS5501-R-272WF, 4140-01-071-2977, 01-071-2977, 4140010712977, 010712977
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | FEB 05, 1979 | 01-071-2977 | 30260 ( FAN, CIRCULATING ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-071-2977
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| A7U6F-1 | 04810 | ASHLAND ELECTRIC PRODUCTS, INC. |
| MF-PS5501-R-272W | T6976 | PEGASUS SAVUNMA SAN. VE TIC.LTD.STI. |
| 729408-1 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
| 021449000 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| 021449 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| MF-PS5501-R-272WF | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
Technical Data | NSN 4140-01-071-2977
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 4.875 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 6.500 INCHES NOMINAL |
| QUANTITY | 1 |
| DRIVE TYPE | DIRECT |
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| INCLOSURE TYPE | FULLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -57.0 DEG CELSIUS AND 71.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | WIRE LEAD |
| PRIME MOVER POWER RATING | 0.080 HORSEPOWER |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 3950.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 200.0 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE AND 6 UNTHREADED HOLE |