NSN 4140-01-092-1097
Part Details | TUBEAXIAL FAN
4140-01-092-1097 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.
Alternate Parts: 010275, 11454624, 4140-01-092-1097, 01-092-1097, 4140010921097, 010921097
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | MAR 19, 1980 | 01-092-1097 | 04244 ( FAN, TUBEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-092-1097
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 010275 | 82877 | ROTRON INCORPORATEDDBA AMETEK ROTRON |
| 11454624 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 4140-01-092-1097
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| DIAMETER | 4.380 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 4.500 INCHES NOMINAL |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| INCLOSURE TYPE | PARTIALLY INCLOSED |
| AMBIENT TEMP AT FULL RATED POWER | -45.6 DEG CELSIUS AND 71.0 DEG CELSIUS |
| ELECTRICAL CONNECTION TYPE | CONNECTOR |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 3200.0 |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 30.8 DC |
| AIR FLOW RATE | 100.000 CUBIC FEET PER MINUTE MINIMUM AND 105.000 CUBIC FEET PER MINUTE MAXIMUM |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT |
| FLOW DIRECTION | INWARD |