NSN 4140-01-179-0403
Part Details | VANEAXIAL FAN
4140-01-179-0403 A nonpositive displacement mechanical device with guide vanes and having an axial fan impeller(s) inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes and pressures.
Alternate Parts: 23E263, 23E26-3, 23E263, 23E26-3, 4140-01-179-0403, 01-179-0403, 4140011790403, 011790403
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 41 | MAY 14, 1984 | 01-179-0403 | 04245 ( FAN, VANEAXIAL ) |
REFERENCE DRAWINGS & PICTURES
FIXED
Cross Reference | NSN 4140-01-179-0403
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 23E26-3 | 72914 | GRIMES AEROSPACE COMPANYDBA HONEYWELL |
| 23E26-3 | 45934 | ONTIC ENGINEERING AND MANUFACTURING,INC. |
Technical Data | NSN 4140-01-179-0403
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | FIXED |
| LENGTH | 5.975 INCHES NOMINAL |
| HOUSING INSIDE DIAMETER | 4.250 INCHES NOMINAL |
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| PRIME MOVER TYPE | AIR TURBINE |
| INCLOSURE TYPE | GUARDED |
| ELECTRICAL CONNECTION TYPE | CONNECTOR |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 400.0 |
| AIR FLOW RATE | 137.000 CUBIC FEET PER MINUTE NOMINAL |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 5.5 INCHES OF WATER |
| FLOW DIRECTION | OUTWARD |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP |
| FEATURES PROVIDED | SAFETY IMPELLER GUARD |