NSN 4140-01-240-4615

Part Details | CENTRIFUGAL FAN

4140-01-240-4615 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 77C721342P001, 77C721342, 034332, DRFSAD3504 190JF, DRFS-AD-3504 190JF, DRFSAD 3516 CW 190JF, DRFS-AD 3516 CW 190JF, 4140-01-240-4615, 01-240-4615, 4140012404615, 012404615

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41SEP 13, 198601-240-461504254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, DUAL IMPELLER, RECTANGULAR OUTLET

Cross Reference | NSN 4140-01-240-4615
Part Number Cage Code Manufacturer
77C721342P00103538LOCKHEED MARTIN CORPORATIONDIV RMS
77C72134203538LOCKHEED MARTIN CORPORATIONDIV RMS
03433282877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFS-AD-3504 190JF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFS-AD 3516 CW 190JF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
Technical Data | NSN 4140-01-240-4615
Characteristic Specifications
STYLE DESIGNATOR FIXED, DUAL IMPELLER, RECTANGULAR OUTLET
WIDTH12.780 INCHES NOMINAL
LENGTH6.880 INCHES NOMINAL
OUTLET INSIDE WIDTH4.000 INCHES NOMINAL
OUTLET INSIDE HEIGHT2.500 INCHES NOMINAL
HEIGHT6.250 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE AND COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
ELECTRICAL CONNECTION TYPE WIRE LEAD
PRIME MOVER POWER RATING100.000 WATTS AND 130.000 WATTS
OPERATING SPEED AT RATED CAPACITY IN RPMB2750.0$$B3050.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE THREE
AIR FLOW RATE360.0 CUBIC FEET PER MINUTE NOMINAL AND 390.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE1.5 INCHES OF WATER
MOUNTING FACILITY TYPE AND QUANTITY8 UNTHREADED HOLE
OUTLET LOCATION TOP
DISCHARGE DIRECTION HORIZONTAL AND VERTICAL DOWN AND VERTICAL UP