NSN 4240-00-788-5307
Part Details | GAS-PARTICULATE FILTER UNIT
4240-00-788-5307 A unit consisting of a power driven fan or blower, gas and particulate filter(s), or gas-particulate filter assembly. It is used for removing biological, chemical, and radiological contaminants from air supplied to buildings, shelters, trailer vans, and the like, or to individual hose connected face masks and/or headpieces.
Alternate Parts: DL5191892, DL5-19-1892, MILF51219, 4240-00-788-5307, 00-788-5307, 4240007885307, 007885307
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
42 | JAN 01, 1960 | 00-788-5307 | 19445 ( FILTER UNIT, GAS-PARTICULATE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4240-00-788-5307
Part Number | Cage Code | Manufacturer |
---|---|---|
DL5-19-1892 | 81361 | EDGEWOOD CHEMICAL BIOLOGICAL CENTERECBC |
MILF51219 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 4240-00-788-5307
Characteristic | Specifications |
---|---|
FILTRATION RATE | 5000.000 CUBIC FEET PER MINUTE NOMINAL |
FILTER TYPE | COMBINATION GAS-PARTICULATE |
GAS/PARTICULATE FILTER MODEL NUMBER | M17A1 |
GAS/PARTICULATE FILTER SPEC/STD | MIL,MIL-F-51224,TYPE NO. M17A1 |
POWER SOURCE | ELECTRIC MOTOR |
CURRENT TYPE | AC |
OPERATING VOLTAGE IN VOLTS | 220.0 NOMINAL |
PHASE | POLYPHASE |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
ELECTROMAGNETIC INTERFERENCE SUPPRESSION | PROVIDED |
BLOWER ASSEMBLY USAGE DESIGN | INDOOR AND OUTDOOR |
RAIN SHIELD | REQUIRED |
INSTALLATION KIT | NOT INCLUDED |
TOOL KIT | NOT INCLUDED |