NSN 4310-00-704-2849

Part Details | ROTARY VACUUM PUMP UNIT

4310-00-704-2849 An assembled unit consisting of a commonly mounted rotary vacuum pump(s), prime mover(s), and the necessary components to provide for a complete operation. It may include vacuum storage tank(s).

Alternate Parts: 1397B, 4310-00-704-2849, 00-704-2849, 4310007042849, 007042849

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
43JAN 01, 196300-704-284929904 ( VACUUM PUMP UNIT, ROTARY )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4310-00-704-2849
Part Number Cage Code Manufacturer
1397B64484SARGENT-WELCH SCIENTIFIC CO
Technical Data | NSN 4310-00-704-2849
Characteristic Specifications
PUMP QUANTITY1
PRIME MOVER TYPE ELECTRIC MOTOR
PUMP BODY MATERIAL ANY ACCEPTABLE
BODY SURFACE TREATMENT ANY ACCEPTABLE
VACUUM RATING0.1 MILLITORR
SYSTEM DESIGN NONCORROSIVE
SPECIFIC GAS FOR WHICH DESIGNED AIR
PUMPING ELEMENT TYPE SLIDING VANE
STAGE QUANTITY2
VAPOR CONDENSATION PREVENTATIVE DEVICE GAS BALLAST VALVING
COOLING MEDIUMD ANY ACCEPTABLE
INTAKE CONNECTION QUANTITY1
INTAKE CONNECTION TYPEP ANY ACCEPTABLE
INTAKE CONNECTION INSIDE DIAMETER1.625 INCHES NOMINAL
DISCHARGE CONNECTION QUANTITY1
DISCHARGE CONNECTION TYPEP ANY ACCEPTABLE
DISCHARGE CONNECTION INSIDE DIAMETER1.625 INCHES NOMINAL
CURRENT TYPE AC
VOLTAGE IN VOLTS115.0
FREQUENCY IN HERTZ60.0
PHASE SINGLE
BRAKE HORSEPOWER REQUIRED1.000
OPERATING SPEED AT RATED CAPACITY IN RPM1725.0
AIR DISPLACEMENT RATE13.3 CUBIC FEET PER MINUTE IN FREE AIR
MOUNTING TYPEB ANY ACCEPTABLE
DRIVE CONNECTION TYPEG ANY ACCEPTABLE
SAFETY DEVICE TYPE OVERLOAD RELAY
CONTROL DEVICE TYPE CONSTANT SPEED
FURNISHED ITEMS BELT GUARD AND V-BELT
OVERALL HEIGHT18.750 INCHES NOMINAL
OVERALL LENGTH25.625 INCHES NOMINAL
OVERALL WIDTH13.125 INCHES NOMINAL
FUNCTIONAL DESCRIPTIONTHIS VACUUM PUMP IS A LARGE CAPACITY HIGH-VACUUM DUO-SEAL PUMP OF TWO STAGE CONSTRUCTION WITH VENTED EXHAUST;THIS PUMP IS DESIGNED FOR THE REMOVAL OF PERMANENT GASES SUCH AS AIR AND HYDROGEN AND CONDENSABLE VAPORS SUCH AS WATER AND SOLVENT; IT IS USED FOR EVACUATING COMPONENTS OF HEATING,VENTILATING COMPONENTS OF THE HEATING,VENTILATING AND AIR CONDITIONING SYS,PROPELLANT TRANSFER SYS AND VARIOUS GAGES DURING MAINTENANCE OPERATIONS; APPLICABLE TO TITAL II MISSILE PROGRAM
ENTRY DATE85-08-15