NSN 4330-00-906-0402
Part Details | FLUID FILTER
4330-00-906-0402 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: GP111150, GP111-150, AAPHS4, 4330-00-906-0402, 00-906-0402, 4330009060402, 009060402
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
43 | JAN 01, 1960 | 00-906-0402 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER

Cross Reference | NSN 4330-00-906-0402
Part Number | Cage Code | Manufacturer |
---|---|---|
GP111-150 | 18170 | DOLLINGER CORP |
AAPHS4 | 18170 | DOLLINGER CORP |
Technical Data | NSN 4330-00-906-0402
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 5 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
BODY LENGTH | 15.500 INCHES NOMINAL |
BODY WIDTH | 8.250 INCHES NOMINAL |
BODY HEIGHT | 20.000 INCHES NOMINAL |
DESIGN TYPE | REUSABLE |
FILTERING ELEMENT QUANTITY | 1 |
FILTRATION RATING IN MICRONS | 1.0 NOMINAL |
MEDIA FOR WHICH DESIGNED | AIR AND Y ANY ACCEPTABLE AND Q ANY ACCEPTABLE AND BR ANY ACCEPTABLE |
MAXIMUM OPERATING PRESSURE | 180.0 POUNDS PER SQUARE INCH |
TEMP RATING | 200.0 DEG FAHRENHEIT NOMINAL |
FIRST INTAKE THREAD SERIES DESIGNATOR | NPT |
FIRST INTAKE NOMINAL THREAD SIZE | 1.500 INCHES |
FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | IDENTICAL TO FIRST INTAKE CONNECTION |
FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
FEATURES PROVIDED | AIR BLEED VALVE AND DRAIN PLUG |
SPECIAL FEATURES | SWING BOLTED CONSTRUCTION;8.000 IN.SERVICE SPACE BELOW FILTER REQUIRED |