NSN 4330-01-139-1925
Part Details | FLUID FILTER
4330-01-139-1925 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: HH9660A24KPTBP, HH-9660-A24-KPTBP, AH9500A24UPTBP, AH-9500-A24-UPTBP, HH9660A24UPTBP, HH-9660-A24-UPTBP, HH9430K24UPT, HH-9430-K24-UPT, HH9430A24UPTBP, HH-9430-A24-UPTBP, HH9400K24UPT, HH-9400-K24-UPT, 4330-01-139-1925, 01-139-1925, 4330011391925, 011391925
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
43 | SEP 26, 1982 | 01-139-1925 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
DIVERTED FLOW BASKET STRAINER W/BOLTED COVER

Cross Reference | NSN 4330-01-139-1925
Part Number | Cage Code | Manufacturer |
---|---|---|
HH-9660-A24-KPTBP | 1EP30 | PALL AEROPOWER CORPORATION |
AH-9500-A24-UPTBP | 60047 | PALL AEROPOWER CORPSUB OF PALL CORP |
HH-9660-A24-UPTBP | 06816 | PALL CORPORATION |
HH-9430-K24-UPT | 06816 | PALL CORPORATION |
HH-9430-A24-UPTBP | 06816 | PALL CORPORATION |
HH-9400-K24-UPT | 06816 | PALL CORPORATION |
Technical Data | NSN 4330-01-139-1925
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 4 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
BODY OUTSIDE DIAMETER | 6.300 INCHES MINIMUM AND 6.720 INCHES MAXIMUM |
BODY HEIGHT | 22.640 INCHES NOMINAL |
DESIGN TYPE | REUSABLE |
FILTERING ELEMENT QUANTITY | 1 |
FILTRATION RATING IN MICRONS | 3.0 ABSOLUTE AND 0.45 NOMINAL |
MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
MAXIMUM OPERATING PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 225.0 DEG FAHRENHEIT MAXIMUM |
DROP PRESSURE | 2.6 POUNDS PER SQUARE INCH |
DIFFERENTIAL PRESSURE | 35.0 POUNDS PER SQUARE INCH |
FIRST INTAKE THREAD SERIES DESIGNATOR | UN |
FIRST INTAKE NOMINAL THREAD SIZE | 1.875 INCHES |
FIRST INTAKE THREAD QUANTITY PER INCH | 12 |
FIRST INTAKE THREAD CLASS | 2B |
FIRST INTAKE THREAD DIRECTION | RIGHT-HAND |
FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | NOT IDENTICAL |
FIRST DISCHARGE THREAD SERIES DESIGNATOR | UN |
FIRST DISCHARGE NOMINAL THREAD SIZE | 1.875 INCHES |
FIRST DISCHARGE THREAD QUANTITY PER INCH | 12 |
FIRST DISCHARGE THREAD CLASS | 2B |
FIRST DISCHARGE THREAD DIRECTION | RIGHT-HAND |
MOUNTING HOLE QUANTITY | 4 |
DISTANCE BETWEEN MOUNTING HOLE CENTERS | 5.422 INCHES MINIMUM AND 5.452 INCHES MAXIMUM |
MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
MOUNTING FACILITY NOMINAL THREAD SIZE | 0.312 INCHES |
FILTERING SYSTEM FOR WHICH DESIGNED | FULL FLOW |
FEATURES PROVIDED | BY-PASS VALVE AND DIFFERENTIAL PRESSURE INDICATOR |
SPECIAL FEATURES | VISUAL INDICATOR W/MANUAL RESET; PORTS PER SAE BOSS J514D |