NSN 4330-01-211-8614
Part Details | FLUID FILTER
4330-01-211-8614 A filter having inlet and outlet connections and designed to be connected in a pipe, tube or hose line. For spin-on, base-mounted filtering devices with integral outer casings, see FILTER ELEMENT, FLUID. Excludes AIR CONDITIONER.
Alternate Parts: HH9660D24UNUCI, HH9660D24UNUCI, 4330-01-211-8614, 01-211-8614, 4330012118614, 012118614
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
43 | JUL 02, 1985 | 01-211-8614 | 32622 ( FILTER, FLUID ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR W/UNTHREADED BOLT HOLES

RECTANGULAR W/UNTHREADED BOLT HOLES

RECTANGULAR W/UNTHREADED BOLT HOLES

RECTANGULAR W/UNTHREADED BOLT HOLES

PLAIN

PLAIN

PLAIN

PLAIN

DIVERTED FLOW BASKET STRAINER W/BOLTED COVER

Cross Reference | NSN 4330-01-211-8614
Part Number | Cage Code | Manufacturer |
---|---|---|
HH9660D24UNUCI | 1EP30 | PALL AEROPOWER CORPORATION |
HH9660D24UNUCI | 17238 | PALL CORPORATIONDBA PALL TRINITY MICRO |
Technical Data | NSN 4330-01-211-8614
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 4 DIVERTED FLOW BASKET STRAINER W/BOLTED COVER |
BODY OUTSIDE DIAMETER | 4.700 INCHES NOMINAL |
BODY HEIGHT | 21.740 INCHES NOMINAL |
DESIGN TYPE | REUSABLE |
FILTERING ELEMENT QUANTITY | 1 |
FILTRATION RATING IN MICRONS | 6.0 ABSOLUTE |
MEDIA FOR WHICH DESIGNED | Y ANY ACCEPTABLE |
MAXIMUM OPERATING PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
TEMP RATING | -45.0 DEG FAHRENHEIT MINIMUM AND 225.0 DEG FAHRENHEIT MAXIMUM |
FIRST INTAKE FLANGE SHAPE STYLE | RECTANGULAR W/UNTHREADED BOLT HOLES |
FIRST INTAKE FLANGE THICKNESS | 0.620 INCHES NOMINAL |
FIRST INTAKE FLANGE LENGTH | 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
FIRST INTAKE FLANGE WIDTH | 2.220 INCHES NOMINAL |
FIRST INTAKE FLANGE FACE STYLE | PLAIN |
FIRST DISCHARGE CONNECTION RELATIONSHIP TO INTAKE CONNECTION | NOT IDENTICAL |
FIRST DISCHARGE FLANGE SHAPE STYLE | RECTANGULAR W/UNTHREADED BOLT HOLES |
FIRST DISCHARGE FLANGE THICKNESS | 0.620 INCHES NOMINAL |
FIRST DISCHARGE FLANGE LENGTH | 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
FIRST DISCHARGE FLANGE WIDTH | 2.220 INCHES NOMINAL |
FIRST DISCHARGE FLANGE FACE STYLE | PLAIN |
BRACKET QUANTITY | 1 |
MOUNTING HOLE QUANTITY | 2 |
DISTANCE BETWEEN MOUNTING HOLE CENTERS | 5.380 INCHES NOMINAL |
MOUNTING HOLE DIAMETER | 0.465 INCHES NOMINAL |
FILTERING SYSTEM FOR WHICH DESIGNED | J$H |
FEATURES PROVIDED | BY-PASS VALVE AND FLOW CONTROL VALVE |
SPECIAL FEATURES | SPLIT FLANGE PER SAE J518C |