NSN 4410-01-230-8024
Part Details | HIGH PRESSURE STEAM BOILER
4410-01-230-8024 A closed metal vessel consisting of a drum(s) or shell and necessary tubes, fittings and direct connected end items. It is designed to convert water into steam by application of heat. Excludes low pressure boilers under 15 pounds (6.804 kg) per square inch (645.2 sq mm) gage steam pressure and evaporators.
Alternate Parts: 584814ESTEAM, 5848-14E-STEAM, 4410-01-230-8024, 01-230-8024, 4410012308024, 012308024
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
44 | APR 17, 1986 | 01-230-8024 | 03292 ( BOILER, STEAM, HIGH PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4410-01-230-8024
Part Number | Cage Code | Manufacturer |
---|---|---|
5848-14E-STEAM | 49937 | R. D. MINERS INCDBA RAY BURNER CO |
Technical Data | NSN 4410-01-230-8024
Characteristic | Specifications |
---|---|
OPERATING POSITION | VERTICAL |
STEAM CAPACITY | 535.000 POUNDS PER HOUR NOMINAL |
HORSEPOWER RATING | 0.5 |
MAXIMUM OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
DRAFT TYPE | FORCED |
FIRING TYPE | OIL |
OIL BURNER QUANTITY | 1 |
WATERWALLS | NOT PROVIDED |
FORCED CIRCULATION FEATURE | PROVIDED |
CURRENT TYPE | B$C |
VOLTAGE RATING | 32.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
PHASE | SINGLE |
IGNITION METHOD | ELECTRICAL |
MARINE SERVICE DESIGN FEATURE | PROVIDED |
MOUNTING METHOD | FLOOR |
MAINTENANCE PARTS | NOT PROVIDED |
PACKAGED BOILER | PROVIDED |
SUPERHEATER | NOT PROVIDED |
END ITEM IDENTIFICATION | BOILER FOUND ONBOARD 210 FT WMEC COAST GUARD VESSELS |