NSN 4520-00-859-5426
Part Details | PORTABLE DUCT TYPE HEATER
4520-00-859-5426 A heater equipped with integral connection(s) for attaching duct(s) to direct heat to engine surface, railroad cars, warehouses, tents, and the like. It is equipped with a blower (fan) and must be mounted on skids, wheels, and the like or capable of being hand-carried. Excludes HEATER, SPACE.
Alternate Parts: MILH27507, HDU13M, PD05WRLEEG03, 4520-00-859-5426, 00-859-5426, 4520008595426, 008595426
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
45 | JAN 01, 1962 | 00-859-5426 | 13028 ( HEATER, DUCT TYPE, PORTABLE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-00-859-5426
Part Number | Cage Code | Manufacturer |
---|---|---|
MILH27507 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
HDU13M | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
PD05WRLEEG03 | 98752 | WARNER ROBINS AIR LOGISTICS CENTER |
Technical Data | NSN 4520-00-859-5426
Characteristic | Specifications |
---|---|
HEAT DELIVERY RATE | 100000.0 BRITISH THERMAL UNIT |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | B220.0$$B440.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | THREE |
CURRENT RATING IN AMPS | B92.0$$B46.0 |
HEATING ELEMENT TYPE | COMBUSTION CHAMBER |
HEAT MEDIUM TYPE | AIR |
MOUNTING TYPE | TRAILER |
HEIGHT | 48.000 INCHES NOMINAL |
DEPTH | 42.000 INCHES NOMINAL |
HEAT OUTLET QUANTITY | 1 |
HEAT DELIVERY DIRECTION | HORIZONTAL |
HEAT DISCHARGE OUTLET TYPE | ADJUSTABLE |
HEAT DIRECTING DEVICE | FLEXIBLE DUCTS |
AIR CIRCULATION DEVICE | SQUIRREL CAGE BLOWER |
QUANTITY | 1 |
SPEED ADJUSTMENTS | 0 TO FULL SPEED |
MAXIMUM AIR FLOW RATE | 600.0 CUBIC FEET PER MINUTE |
PRIME MOVER TYPE | ELECTRIC MOTOR |
CIRCULATED AIR TYPE | HEATED |
OPERATING CONTROL TYPE | THERMOSTATIC |
SPECIAL FEATURES | WEIGHT,DRY,1300 POUNDS;LENGTH 70 INCHES EXCLUDING TOW BAR PROVISIONS;ENVIRONMENTAL LIMITS -80F TO +160F;OPERATING ALTITUDE,SEA LEVEL TO 5,000FT;POWER CONSUMPTION 92 AMPS(220V);46 AMPS(440V);INPUT REQUIREMENT MECHANICAL/PNEUMATIC;METHOD OF COUPLING, DIRECT;RATED DISCHARGE 36 LBS PER MI,12"WC AND 200F OUTLET TEMP;TOWING PROVISIONS-TOW BAR WITH LUNETTE EYE;AUTOMATIC CONTROL;CONTINUOUS DUTY CYCLE;UNSYMMETRICAL MOUNTING MEANS;TIE DOWN PROVISION-RINGS;TIRE SIZE 6.00X9;PNEUMATIC TIRE;SPARK-PROOF CABINET;EXPLOSION-PROOF REQUIREMENTS;2 8 IN. INSULATED DUCTS,15 FT. L;50 FT POWER CABLE 220/440 AC |
SPECIFICATION/STANDARD DATA | 81349-MIL-275075C GOVERNMENT SPECIFICATION |
NONDEFINITIVE SPEC/STD DATA | 2 CLASS |
FUNCTIONAL CLASSIFICATION | JJ-1.3 |
FUNCTIONAL DESCRIPTION | THE HDU-13/M HEATER IS INTENDED FOR USE IN HANGARS AND NOSE DOCKS FOR FUEL CELL REPAIR OPERATIONS AND FOR THE HEATING OF AIRCRAFT COMPARTMENTS BY DELIVERLY OF HEATED AIR AT MODERATE PRESSURES THROUGH AN AIRBORNE DUCT SYS |
RELATIONSHIP TO SIMILAR EQUIPMENT | SIMILAR TO MODELS H40,NSN 4520-00-817-1793,MODEL H40-1,NSN 4520-00-067-7572 AND MODEL H41,NSN 4520-00-057-9382 |
REFERENCE DATA AND LITERATURE | AF TO. 35E7-6-9-1 |
ENTRY DATE | 75-06-01 |