NSN 4520-00-859-5426

Part Details | PORTABLE DUCT TYPE HEATER

4520-00-859-5426 A heater equipped with integral connection(s) for attaching duct(s) to direct heat to engine surface, railroad cars, warehouses, tents, and the like. It is equipped with a blower (fan) and must be mounted on skids, wheels, and the like or capable of being hand-carried. Excludes HEATER, SPACE.

Alternate Parts: MILH27507, HDU13M, PD05WRLEEG03, 4520-00-859-5426, 00-859-5426, 4520008595426, 008595426

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
45JAN 01, 196200-859-542613028 ( HEATER, DUCT TYPE, PORTABLE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-00-859-5426
Part Number Cage Code Manufacturer
MILH2750781349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
HDU13M81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
PD05WRLEEG0398752WARNER ROBINS AIR LOGISTICS CENTER
Technical Data | NSN 4520-00-859-5426
Characteristic Specifications
HEAT DELIVERY RATE100000.0 BRITISH THERMAL UNIT
CURRENT TYPE AC
VOLTAGE IN VOLTSB220.0$$B440.0
FREQUENCY IN HERTZ60.0
PHASE THREE
CURRENT RATING IN AMPSB92.0$$B46.0
HEATING ELEMENT TYPE COMBUSTION CHAMBER
HEAT MEDIUM TYPE AIR
MOUNTING TYPE TRAILER
HEIGHT48.000 INCHES NOMINAL
DEPTH42.000 INCHES NOMINAL
HEAT OUTLET QUANTITY1
HEAT DELIVERY DIRECTION HORIZONTAL
HEAT DISCHARGE OUTLET TYPE ADJUSTABLE
HEAT DIRECTING DEVICE FLEXIBLE DUCTS
AIR CIRCULATION DEVICE SQUIRREL CAGE BLOWER
QUANTITY1
SPEED ADJUSTMENTS 0 TO FULL SPEED
MAXIMUM AIR FLOW RATE600.0 CUBIC FEET PER MINUTE
PRIME MOVER TYPE ELECTRIC MOTOR
CIRCULATED AIR TYPE HEATED
OPERATING CONTROL TYPE THERMOSTATIC
SPECIAL FEATURESWEIGHT,DRY,1300 POUNDS;LENGTH 70 INCHES EXCLUDING TOW BAR PROVISIONS;ENVIRONMENTAL LIMITS -80F TO +160F;OPERATING ALTITUDE,SEA LEVEL TO 5,000FT;POWER CONSUMPTION 92 AMPS(220V);46 AMPS(440V);INPUT REQUIREMENT MECHANICAL/PNEUMATIC;METHOD OF COUPLING, DIRECT;RATED DISCHARGE 36 LBS PER MI,12"WC AND 200F OUTLET TEMP;TOWING PROVISIONS-TOW BAR WITH LUNETTE EYE;AUTOMATIC CONTROL;CONTINUOUS DUTY CYCLE;UNSYMMETRICAL MOUNTING MEANS;TIE DOWN PROVISION-RINGS;TIRE SIZE 6.00X9;PNEUMATIC TIRE;SPARK-PROOF CABINET;EXPLOSION-PROOF REQUIREMENTS;2 8 IN. INSULATED DUCTS,15 FT. L;50 FT POWER CABLE 220/440 AC
SPECIFICATION/STANDARD DATA81349-MIL-275075C GOVERNMENT SPECIFICATION
NONDEFINITIVE SPEC/STD DATA2 CLASS
FUNCTIONAL CLASSIFICATIONJJ-1.3
FUNCTIONAL DESCRIPTIONTHE HDU-13/M HEATER IS INTENDED FOR USE IN HANGARS AND NOSE DOCKS FOR FUEL CELL REPAIR OPERATIONS AND FOR THE HEATING OF AIRCRAFT COMPARTMENTS BY DELIVERLY OF HEATED AIR AT MODERATE PRESSURES THROUGH AN AIRBORNE DUCT SYS
RELATIONSHIP TO SIMILAR EQUIPMENTSIMILAR TO MODELS H40,NSN 4520-00-817-1793,MODEL H40-1,NSN 4520-00-067-7572 AND MODEL H41,NSN 4520-00-057-9382
REFERENCE DATA AND LITERATUREAF TO. 35E7-6-9-1
ENTRY DATE75-06-01