NSN 4520-01-219-6481

Part Details | STEAM-HOT WATER AIR CIRCULATING UNIT HEATER

4520-01-219-6481 A heating device which is connected to a central source of hot water or steam, for the purpose of distributing heat, by means of a motor-driven fan, throughout a room or building. By introducing outside air, it may also be utilized for ventilating purposes or a combination of heating and ventilating.

Alternate Parts: FXY02, FCBB02, B12A002, 4520-01-219-6481, 01-219-6481, 4520012196481, 012196481

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
45OCT 31, 198501-219-648104874 ( UNIT HEATER, AIR CIRCULATING, STEAM-HOT WATER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4520-01-219-6481
Part Number Cage Code Manufacturer
FXY0216685INTERNATIONAL ENVIRONMENTAL CORP
FCBB0260532TRANE U.S. INC.DBA TRANE
B12A00260532TRANE U.S. INC.DBA TRANE
Technical Data | NSN 4520-01-219-6481
Characteristic Specifications
HEAT DELIVERY RATE24084.0 BRITISH THERMAL UNIT
CURRENT TYPE AC
VOLTAGE IN VOLTS115.0
FREQUENCY IN HERTZ60.0
PHASE SINGLE
CURRENT RATING IN AMPS0.85
HEATING ELEMENT TYPE HOT WATER COIL
HEAT MEDIUM TYPE HOT WATER
MOUNTING TYPE FLOOR SURFACE, FREE STANDING, NONDUCTED
HEIGHT25.000 INCHES NOMINAL
WIDTH31.500 INCHES NOMINAL
DEPTH9.000 INCHES NOMINAL
HEAT OUTLET QUANTITY1
HEAT DELIVERY DIRECTION VERTICAL
HEAT DISCHARGE OUTLET TYPE STATIONARY
HEAT DIRECTING DEVICE DIRECTIONAL GRILLE
AIR CIRCULATION DEVICE PROPELLER FAN
QUANTITY1
SPEED ADJUSTMENTS THREE SPEED
MAXIMUM AIR FLOW RATE230.0 CUBIC FEET PER MINUTE
PRIME MOVER TYPE ELECTRIC MOTOR
CIRCULATED AIR TYPE HEATED
AIR FILTER TYPE REPLACEABLE PREFORMED