NSN 4810-01-126-9894

Part Details | DIRECTIONAL CONTROL LINEAR VALVE

4810-01-126-9894 A manually or power operated valve having three or more ports. The direction of the flow through the various ports is controlled by either one or more reciprocating slide(s) or spool(s) with recess areas which mate with ports in an integral or replaceable ported sleeve, or one or more poppet(s). It is designed to change the direction of fluid flow from one valve port to another. An off (no flow) position is not a flow pattern. The valve is designed to actuate various components of a fluid system. A power operated valve may have a manual override. For items which stop, start, or change the flow of fluid, see: VALVE, SOLENOID. Excludes VALVE, PLUG. See also SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; and VALVE ASSEMBLY.

Alternate Parts: D3W1BY, D3W-1-B-Y, D3W20BNYC, D3W1BNYC, D3W1BY, D3W-1-B-Y, 4810-01-126-9894, 01-126-9894, 4810011269894, 011269894

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48FEB 21, 198201-126-989461929 ( VALVE, LINEAR, DIRECTIONAL CONTROL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4810-01-126-9894
Part Number Cage Code Manufacturer
D3W-1-B-Y57760PARKER HANNIFIN CORPORATIONDBA HYDRAULIC PUMP/MOTOR DUV DIV
D3W20BNYC09990PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC VALVE DIV
D3W1BNYC09990PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC VALVE DIV
D3W-1-B-Y09990PARKER-HANNIFIN CORPORATIONDBA HYDRAULIC VALVE DIV
Technical Data | NSN 4810-01-126-9894
Characteristic Specifications
FLOW PATTERN QUANTITY2
VALVE DISCHARGE FLOW RATE20.0 GALLONS PER MINUTE
MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED160.0 DEG FAHRENHEIT OIL, HYDRAULIC
VALVE OPERATION METHOD SOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE120.0 AC
PHASE SINGLE
CURRENT RATING IN AMPS0.720
FEATURES PROVIDED SUBPLATE MOUNTED