NSN 4810-01-179-2883

Part Details | SOLENOID VALVE

4810-01-179-2883 A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.

Alternate Parts: 7397501D 1IN., 739-7501D 1IN., 73975011IN., 739-7501-1IN., 7397501, 739-7501, 73907501000, 739-07501-000, 73907501000, 739-07501-000, 4810-01-179-2883, 01-179-2883, 4810011792883, 011792883

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
48MAY 16, 198401-179-288310998 ( VALVE, SOLENOID )
REFERENCE DRAWINGS & PICTURES

CROSS

Cross Reference | NSN 4810-01-179-2883
Part Number Cage Code Manufacturer
739-7501D 1IN.09647AQUA-CHEM INC.
739-7501-1IN.09647AQUA-CHEM INC.
739-750109647AQUA-CHEM INC.
739-07501-00009647AQUA-CHEM INC.
739-07501-0000EXU3AQUA-CHEM, INC.
Technical Data | NSN 4810-01-179-2883
Characteristic Specifications
STYLE DESIGNATORA CROSS
FACE TO FACE DISTANCE6.750 INCHES
FIRST CONNECTION FACE TO CENTERLINE DISTANCE4.125 INCHES
VALVE SIZE1.250 INCHES
FLOW CONTROL DEVICE DISK
VALVE OPERATION METHOD SOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE110.0 AC
FREQUENCY IN HERTZ60.0
PHASE SINGLE
CURRENT RATING IN AMPS17.900
FLOW CONTROL DEVICE NORMAL OPERATION POSITION OPEN
MOUNTING POSITIONR$DVT