NSN 4820-00-038-7018
Part Details | SAFETY RELIEF VALVE
4820-00-038-7018 A valve designed to automatically release excessive pressures. It is actuated by static pressure upstream of the valve and is used as a safety valve or relief valve, and may be set to close at a predetermined pressure. It is not designed for regulation of continuously fluctuating loads. It may be inline or cartridge (manifold) design. Excludes VALVE (1), RELIEF, PRESSURE AND TEMPERATURE.
Alternate Parts: 20318, MILV24332, MILV24332GRB1 12 2501530F, MILV24332GRB1 1-2 250-15-30F, 20318, 4820-00-038-7018, 00-038-7018, 4820000387018, 000387018
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 48 | NOV 10, 1972 | 00-038-7018 | 05488 ( VALVE, SAFETY RELIEF ) |
REFERENCE DRAWINGS & PICTURES
ANGLE
Cross Reference | NSN 4820-00-038-7018
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 20318 | 01343 | ANDERSON GREENWOOD LPDBA ANDERSON GREENWOOD CROSBY |
| MILV24332 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MILV24332GRB1 1-2 250-15-30F | 03950 | NAVAL INVENTORY CONTROL POINTMECHANICSBURG |
| 20318 | 15187 | PENTAIR VALVES & CONTROLS US LPDBA NAVY PRODUCT TEAM |
Technical Data | NSN 4820-00-038-7018
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | ANGLE |
| FLOW CONTROL DEVICE | DISK |
| VALVE DISCHARGE FLOW RATE | 10.0 GALLONS PER MINUTE |
| VALVE OPERATION METHOD | AUTOMATIC |
| RENEWABLE SEAT RING TYPE | THREADED |
| BONNET TYPE | INSIDE SPRING |
| BONNET ATTACHMENT METHOD | THREADED |
| DISK LOADING METHOD | SPRING |
| OPENING PRESSURE SETTING | 30.0 POUNDS PER SQUARE INCH |
| ADJUSTABLE PRESSURE RANGE | 15.0 TO 30.0 POUNDS PER SQUARE INCH |
| FEATURES PROVIDED | PRESSURE TIGHT OUTLET SIDE |
| TEST DATA DOCUMENT | 81349-MIL-S-901 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| NONDEFINITIVE SPEC/STD DATA | B GRADE |