NSN 5905-00-010-8077

Part Details | WIRE WOUND FIXED RESISTOR

5905-00-010-8077 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self supporting. Opposition to the flow of current is an inherent property of the resistance wire and is manifest by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE.

Alternate Parts: RW79U1502F, MILR265, MIL-R-26/5, 2124290PT48, SMB2003893, SM-B-2003893, RS2B1502F, RS2BU153V, RS2BU000B15001F, 5905-00-010-8077, 00-010-8077, 5905000108077, 000108077

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 13, 196800-010-807700010 ( RESISTOR, FIXED, WIRE WOUND )
REFERENCE DRAWINGS & PICTURES

AXIAL TERMINAL EACH END

Cross Reference | NSN 5905-00-010-8077
Part Number Cage Code Manufacturer
RW79U1502F81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-R-26/581349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
2124290PT4810001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
SM-B-200389380063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
RS2B1502F91637VISHAY DALE ELECTRONICS, LLCDBA VISHAY INTERTECHNOLOGY
RS2BU153V91637VISHAY DALE ELECTRONICS, LLCDBA VISHAY INTERTECHNOLOGY
RS2BU000B15001F91637VISHAY DALE ELECTRONICS, LLCDBA VISHAY INTERTECHNOLOGY
Technical Data | NSN 5905-00-010-8077
Characteristic Specifications
ELECTRICAL RESISTANCE15.000 KILOHMS
RESISTANCE TOLERANCE IN PERCENTM1.000/P1.000
POWER DISSIPATION RATING IN WATTS3.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUSM20.0/P20.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUSM55.0/P275.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR4 AXIAL TERMINAL EACH END
BODY DIAMETER0.155 INCHES MINIMUM AND 0.219 INCHES MAXIMUM
BODY LENGTH0.498 INCHES MINIMUM AND 0.622 INCHES MAXIMUM
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH1.500 INCHES NOMINAL
CUBIC MEASURE0.023 CUBIC INCHES
TEST DATA DOCUMENT10001-2124290 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
CRITICALITY CODE JUSTIFICATIONTEST