NSN 5910-00-063-3574
Part Details | CERAMIC DIELECTRIC FIXED CAPACITOR
5910-00-063-3574 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Alternate Parts: 2443008X5S0471M, 2443-008X5S0-471M, G3200061, G320006-1, 2443008X5S0471M, 2443-008-X5S0-471M, 5910-00-063-3574, 00-063-3574, 5910000633574, 000633574
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-063-3574 | 00007 ( CAPACITOR, FIXED, CERAMIC DIELECTRIC ) |
REFERENCE DRAWINGS & PICTURES
W/THD MTG BUSHING, TERMINALS ON OPPOSITE ENDS
FEEDTHROUGH
Cross Reference | NSN 5910-00-063-3574
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2443-008X5S0-471M | 72982 | ERIE SPECIALTY PRODUCTS INC |
| G320006-1 | 24930 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR |
| 2443-008-X5S0-471M | 59660 | TUSONIX, INC. |
Technical Data | NSN 5910-00-063-3574
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 470.000 PICOFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -20.00 TO +20.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
| VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | BCNM22.0 TO +22.0 WITHOUT VOLTAGE APPLIED |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | W/THD MTG BUSHING, TERMINALS ON OPPOSITE ENDS |
| WIDTH ACROSS FLATS | 0.312 INCHES NOMINAL |
| BODY LENGTH | 0.468 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | FEEDTHROUGH |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 0.391 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.051 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| NOMINAL THREAD SIZE | 0.250 INCHES |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL SURFACE TREATMENT | COPPER |