NSN 5910-00-106-6982

Part Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-106-6982 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Alternate Parts: MILC39651, MILC3965-1, CL16BM500UPG, 5910-00-106-6982, 00-106-6982, 5910001066982, 001066982

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 24, 196800-106-698200008 ( CAPACITOR, FIXED, ELECTROLYTIC )
REFERENCE DRAWINGS & PICTURES

W/THD BUSHING MTG, TERMINAL(S) ON ONE END

NO COMMON OR GROUNDED ELECTRODE(S)

Cross Reference | NSN 5910-00-106-6982
Part Number Cage Code Manufacturer
MILC3965-181349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
CL16BM500UPG81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 5910-00-106-6982
Characteristic Specifications
CAPACITANCE VALUE PER SECTION50.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION-15.00 TO +75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION90.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE W/THD BUSHING MTG, TERMINAL(S) ON ONE END
BODY DIAMETER0.875 INCHES NOMINAL
BODY LENGTH0.762 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY1 SOLDER STUD AND 1 TAB, SOLDER LUG
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
CAPACITIVE ELECTRODE MATERIAL TANTALUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT2.0000
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
TEST DATA DOCUMENT81349-MIL-C-3965 TO 1 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
ANODE TYPE SOLID