NSN 5920-00-931-0593
Part Details | CARTRIDGE FUSE
5920-00-931-0593 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.
Alternate Parts: ASC1559795, M234192020, M23419-2-020, MILF234192, MILF23419-2, MILPRF234192, MIL-PRF-23419/2, FM02A125V4A, FM02A1125V4A, FM02125V4A, FM02-125V4A, 41861520, 418615-20, 5920-00-931-0593, 00-931-0593, 5920009310593, 009310593
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 14, 1966 | 00-931-0593 | 00248 ( FUSE, CARTRIDGE ) |
REFERENCE DRAWINGS & PICTURES
PLUG-IN TYPE

Cross Reference | NSN 5920-00-931-0593
Part Number | Cage Code | Manufacturer |
---|---|---|
ASC1559795 | Z4779 | ASC PTY LTD |
M23419-2-020 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MILF23419-2 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-PRF-23419/2 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
FM02A125V4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
FM02A1125V4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
FM02-125V4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
418615-20 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5920-00-931-0593
Characteristic | Specifications |
---|---|
BODY STYLE | PLUG-IN TYPE |
OVERALL LENGTH | 0.518 INCHES NOMINAL |
TERMINAL LENGTH | 0.170 INCHES NOMINAL |
BODY LENGTH | 0.348 INCHES NOMINAL |
OVERALL DIAMETER | 0.250 INCHES NOMINAL |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER | 0.100 INCHES MINIMUM AND 0.108 INCHES MAXIMUM |
CONTINUOUS CURRENT RATING IN AMPS | 4.000 |
MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 10.0 200 PCT OF CURRENT RATING |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 300.0 |
INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
TERMINAL SURFACE TREATMENT | NICKEL |
FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
TEST DATA DOCUMENT | 81349-MIL-F-23419 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-F-23419 TO 2 GOVERNMENT SPECIFICATION |
TERMINAL MATERIAL | COPPER |