NSN 5920-01-095-1826
Part Details | ELECTRICAL SURGE ARRESTER
5920-01-095-1826 A circuit-protecting device which provides a discharge path for abnormal surges of high potential while consuming little or no power at normal operating voltage. Excludes items which absorb continuously recurring cyclic pulses. For resistors which are sensitive to voltage changes or used as elements in surge arresters, see RESISTOR, VOLTAGE SENSITIVE. See also ABSORBER, OVERVOLTAGE; AND CUTOUT DISK, PROTECTIVE.
Alternate Parts: UBD1.0, UBD-1.0, UBD1.0KV, UBD1.0, UBD-1.0, 8508206, 85082-06, UBD1.0, UBD1.0KV, SMC8008342, SM-C-800834-2, 5920-01-095-1826, 01-095-1826, 5920010951826, 010951826
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAY 23, 1980 | 01-095-1826 | 00381 ( ARRESTER, ELECTRICAL SURGE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5920-01-095-1826
Part Number | Cage Code | Manufacturer |
---|---|---|
UBD-1.0 | 1E9M5 | C P CLARE CORP |
UBD1.0KV | 71744 | CHICAGO MINIATURE LIGHTING LLCDBA CHICAGO MINIATURE OPTOELECTRON |
UBD-1.0 | 71482 | CP CLARE CORPNORTH AMERICAN SALES OPERATIONS |
85082-06 | 16236 | DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL |
UBD1.0 | 1W8F9 | HIGH ENERGY DEVICES, LLC |
UBD1.0KV | R1120 | SATAIR A/S |
SM-C-800834-2 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5920-01-095-1826
Characteristic | Specifications |
---|---|
BODY MATERIAL | CERAMIC AND METAL |
USAGE DESIGN | INDOOR AND OUTDOOR |
OVERALL LENGTH | 1.812 INCHES MAXIMUM |
OVERALL DIAMETER | 0.620 INCHES MAXIMUM |
MOUNTING METHOD | TERMINALS, WIRE LEAD |
MOUNTING CONFIGURATION | TWO AXIAL LEADS 0.312 IN. MAX ON THE LEFT 0.625 IN. MAX ON THE RIGHT |
BREAKDOWN VOLTAGE | 990.000 VOLTS MINIMUM AND 1.100 KILOVOLTS MAXIMUM |
TERMINAL TYPE | WIRE LEAD |
TERMINAL QUANTITY | 2 |