NSN 5920-01-260-8502
Part Details | PLUG FUSE
5920-01-260-8502 A fuse which mounts by means of a screw base.
Alternate Parts: AA5547209, AA55472-09, AA55472, WF7913009, WF791/3-009, WF7913, WF791-3, 5920-01-260-8502, 01-260-8502, 5920012608502, 012608502
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | AUG 05, 1987 | 01-260-8502 | 00388 ( FUSE, PLUG ) |
REFERENCE DRAWINGS & PICTURES
S-BASE

Cross Reference | NSN 5920-01-260-8502
Part Number | Cage Code | Manufacturer |
---|---|---|
AA55472-09 | 58536 | FEDERAL COMMERCIAL ITEM DESCRIPTIONPROMULGATED BY GENERAL SERVICES |
AA55472 | 58536 | FEDERAL COMMERCIAL ITEM DESCRIPTIONPROMULGATED BY GENERAL SERVICES |
WF791/3-009 | 81348 | FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES |
WF791-3 | 81348 | FEDERAL SPECIFICATIONSPROMULGATED BY GENERAL SERVICES |
Technical Data | NSN 5920-01-260-8502
Characteristic | Specifications |
---|---|
BODY STYLE | S-BASE |
OVERALL LENGTH | 1.250 INCHES MAXIMUM |
TERMINAL LENGTH | 0.688 INCHES MINIMUM AND 0.719 INCHES MAXIMUM |
OVERALL DIAMETER | 1.250 INCHES MAXIMUM |
CONTINUOUS CURRENT RATING IN AMPS | 1.400 |
MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 12.0 200 PCT OF CURRENT RATING |
INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
TEST DATA DOCUMENT | 81348-W-F-791 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81348-W-F-791 TO 3 GOVERNMENT SPECIFICATION |
CASE MATERIAL | 0$DPC0000$DGS0000 |