NSN 5925-00-406-9804
Part Details | CIRCUIT BREAKER BOX
5925-00-406-9804 An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see SWITCH BOX; JACK BOX; TERMINAL BOX; and DISTRIBUTION BOX. For boxes designed to mount and protect but do not include circuit breakers, see CIRCUIT BREAKER BOX SUBASSEMBLY. See also INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; and CABINET, ELECTRICAL EQUIPMENT.
Alternate Parts: TRP270R2S, TPL270R, TL270RH, 5925-00-406-9804, 00-406-9804, 5925004069804, 004069804
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | APR 27, 1970 | 00-406-9804 | 19365 ( CIRCUIT BREAKER BOX ) |
REFERENCE DRAWINGS & PICTURES
4 POINT-RECTANGULAR

RECTANGULAR, FLUSH MOUNTING

Cross Reference | NSN 5925-00-406-9804
Part Number | Cage Code | Manufacturer |
---|---|---|
TRP270R2S | 60969 | GENERAL ELECTRIC COELECTRICAL DISTRIBUTION AND CONTROL |
TPL270R | 60969 | GENERAL ELECTRIC COELECTRICAL DISTRIBUTION AND CONTROL |
TL270RH | 60969 | GENERAL ELECTRIC COELECTRICAL DISTRIBUTION AND CONTROL |
Technical Data | NSN 5925-00-406-9804
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECTANGULAR, FLUSH MOUNTING |
OVERALL DEPTH | 4.406 INCHES NOMINAL |
OVERALL HEIGHT | 9.999 INCHES NOMINAL |
OVERALL WIDTH | 7.062 INCHES NOMINAL |
MATERIAL | STEEL |
SURFACE TREATMENT | PAINT |
ENTRANCE TYPE AND QUANTITY | 11 FOUR CONCENTRIC KNOCKOUT |
ENTRANCE DIAMETER NUMERIC DESIGNATOR | 0.500/0.750/1.000 |
MOUNTING METHOD | UNTHREADED HOLE |
STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 7.000 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
SYSTEM FOR WHICH DESIGNED | THREE WIRE SINGLE PHASE |
MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 70.0 |
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 240.0 |
GROUND CONNECTION TYPE FOR WHICH DESIGNED | SOLID |
CIRCUIT BREAKER TYPE AND QUANTITY | 2 SINGLE POLE |
CIRCUIT BREAKER CURRENT RATING IN AMPS | 30.0 |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |