NSN 5925-00-518-9761

Part Details | CIRCUIT BREAKER

5925-00-518-9761 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 291789, 613878250VAC1, 61-387-8-250VAC1, 260022100, 260-0221-00, 5925-00-518-9761, 00-518-9761, 5925005189761, 005189761

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-518-976100136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-MULTIPLE ACTUATOR TYPE

Cross Reference | NSN 5925-00-518-9761
Part Number Cage Code Manufacturer
29178999993DEPARTMENT OF THE NAVY
61-387-8-250VAC174193EATON CORPHEINEMANN PRODUCTS
260-0221-0013499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
Technical Data | NSN 5925-00-518-9761
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY4 TAB W/SCREW
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
OVERALL HEIGHT1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
OVERALL WIDTH2.680 INCHES MINIMUM AND 2.700 INCHES MAXIMUM
BODY LENGTH5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY WIDTH1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BODY HEIGHT2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
BOSS HEIGHT0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE0.190 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED