NSN 5925-00-626-4191

Part Details | CIRCUIT BREAKER

5925-00-626-4191 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 31077, 31-077, 000310077, 00031-0077, 5925-00-626-4191, 00-626-4191, 5925006264191, 006264191

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-626-419100136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5925-00-626-4191
Part Number Cage Code Manufacturer
31-07793568HARSCO CORPBMY-COMBAT SYSTEMS DIV
00031-007793568HARSCO CORPBMY-COMBAT SYSTEMS DIV
Technical Data | NSN 5925-00-626-4191
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 SCREW
RESET METHOD AUTOMATIC
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION RESET
ACTUATOR POSITION DESIGNATION AT POLE THREE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF