NSN 5925-00-803-4424
Part Details | CIRCUIT BREAKER
5925-00-803-4424 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: 8376916, 12045375, 5925008034424, AA5557101002, A-A-55571/01-002, AA55571, A-A-55571, 195901, M1351612, M13516/1-2, MILC135161, MIL-C-13516/1, MS390622, MS39062-2, M340252R91, M1351612, M13516/1-2, C9115520, C9115-5-20, 9115520, 9115-5-20, AA5557101002, AA55571/01-002, 5925-00-803-4424, 00-803-4424, 5925008034424, 008034424
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1962 | 00-803-4424 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
SINGLE POLE TYPE

Cross Reference | NSN 5925-00-803-4424
Part Number | Cage Code | Manufacturer |
---|---|---|
8376916 | 19204 | ARMY, UNITED STATES DEPARTMENT OFTHE |
12045375 | 88853 | BCP CONSTRUCTION PRODUCTSDIV OF TEREX CORP |
5925008034424 | SCY13 | E.C.A ETABLISSEMENTCENTRALD'APPROVISIONNEMENT DES |
A-A-55571/01-002 | 58536 | FEDERAL COMMERCIAL ITEM DESCRIPTIONPROMULGATED BY GENERAL SERVICES |
A-A-55571 | 58536 | FEDERAL COMMERCIAL ITEM DESCRIPTIONPROMULGATED BY GENERAL SERVICES |
195901 | 23382 | FWD SEAGRAVE HOLDINGS, LP |
M13516/1-2 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-C-13516/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MS39062-2 | 96906 | MILITARY STANDARDSPROMULGATED BY MILITARY DEPARTMENTS |
M340252R91 | 92679 | NAVISTAR INTL CORPMELROSE PARK ENGINE PLANT LOCATION |
M13516/1-2 | 0158B | PSA PEUGEOT-CITROEN ESPANA, SA |
C9115-5-20 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
9115-5-20 | 96214 | RAYTHEON COMPANYDBA RAYTHEON |
AA55571/01-002 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
Technical Data | NSN 5925-00-803-4424
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |
RESET METHOD | AUTOMATIC |
BODY STYLE | SINGLE POLE TYPE |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
BODY LENGTH | 2.000 INCHES NOMINAL |
BODY WIDTH | 1.813 INCHES NOMINAL |
BODY HEIGHT | 1.875 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.625 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM |
UNTHREADED MOUNTING HOLE DIAMETER | 0.174 INCHES NOMINAL |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT |
STORAGE TYPE | E ANY ACCEPTABLE |
FRAGILITY FACTOR | MODERATELY RUGGED |