NSN 5925-01-026-0883

Part Details | CIRCUIT BREAKER

5925-01-026-0883 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 112638002, 11263800-2, CF3Z562, CF3-Z56-2, CF3Z562W, CF3-Z56-2W, 5925-01-026-0883, 01-026-0883, 5925010260883, 010260883

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 15, 197601-026-088300136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-MULTIPLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-026-0883
Part Number Cage Code Manufacturer
11263800-217773BALLISTIC MISSILE DEFENSE SYSTEMSCOMMAND
CF3-Z56-274193EATON CORPHEINEMANN PRODUCTS
CF3-Z56-2WL3330HEINEMANN ELECTRIC CANADA INCDIVISION OF EATON CORP
Technical Data | NSN 5925-01-026-0883
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 SCREW
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE AND 6 SLOT
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH5.768 INCHES MINIMUM AND 5.832 INCHES MAXIMUM
BODY WIDTH3.046 INCHES MINIMUM AND 3.110 INCHES MAXIMUM
BODY HEIGHT2.577 INCHES MINIMUM AND 2.641 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.515 INCHES MINIMUM AND 3.579 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.994 INCHES MINIMUM AND 1.058 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.718 INCHES MINIMUM AND 2.782 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.994 INCHES MINIMUM AND 1.058 INCHES MAXIMUM
BOSS HEIGHT0.187 INCHES MINIMUM AND 0.251 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MOUNTING SLOT WIDTH0.164 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE TWO
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS2.5 AC AND 1.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 50.0 DC
SWITCH TERMINAL TYPE TURRET
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED