NSN 5925-01-111-1307

Part Details | CIRCUIT BREAKER

5925-01-111-1307 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 58399TCK147.5A, 583-99TC-K14-7.5A, 5925-01-111-1307, 01-111-1307, 5925011111307, 011111307

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 11, 198101-111-130700136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-111-1307
Part Number Cage Code Manufacturer
583-99TC-K14-7.5A06402OAKLAND INDUSTRIES LTDDBA E-T-A CIRCUIT BREAKERS
Technical Data | NSN 5925-01-111-1307
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 SCREW
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BUSHING LENGTH6.35 MILLIMETERS NOMINAL
BODY LENGTH25.5 MILLIMETERS NOMINAL
BODY WIDTH45.0 MILLIMETERS NOMINAL
BODY HEIGHT35.5 MILLIMETERS NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH12.8 MILLIMETERS NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH15.0 MILLIMETERS NOMINAL
THREAD SERIES DESIGNATOR UNS
NOMINAL THREAD SIZE0.375 INCHES
THREAD QUANTITY PER INCH27
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED CORROSION RESISTANT AND EXPLOSION RESISTANT AND HUMIDITY RESISTANT