NSN 5925-01-146-1293
Part Details | CIRCUIT BREAKER
5925-01-146-1293 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: 446SHNSI300A, 44-6-S-H-N-SI-300A, SMA3173352, SM-A-317335-2, 5925-01-146-1293, 01-146-1293, 5925011461293, 011461293
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 25, 1983 | 01-146-1293 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR DIMENSIONAL ENVELOPE
Cross Reference | NSN 5925-01-146-1293
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 44-6-S-H-N-SI-300A | 06402 | OAKLAND INDUSTRIES LTDDBA E-T-A CIRCUIT BREAKERS |
| SM-A-317335-2 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5925-01-146-1293
| Characteristic | Specifications |
|---|---|
| POLE QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
| RESET METHOD | MANUAL |
| BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| CASE MATERIAL | PLASTIC |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| OVERALL LENGTH | 4.090 INCHES NOMINAL |
| OVERALL HEIGHT | 1.580 INCHES NOMINAL |
| OVERALL WIDTH | 3.940 INCHES NOMINAL |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| ACTUATOR FUNCTION | RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 5.0 DC |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 28.0 DC |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT AND HUMIDITY RESISTANT |
| TEST DATA DOCUMENT | 80063-SM-A-317335 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| STORAGE TYPE | E ANY ACCEPTABLE |
| UNPACKAGED UNIT WEIGHT | 30.000 OUNCES |