NSN 5925-01-208-6344

Part Details | CIRCUIT BREAKER

5925-01-208-6344 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: S910002001, S91-0002-001, 109250, 109-250, 413S14LN250, 41-3-S14-LN2-50, 5925-01-208-6344, 01-208-6344, 5925012086344, 012086344

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 16, 198501-208-634400136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-01-208-6344
Part Number Cage Code Manufacturer
S91-0002-00114304HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION
109-25065642LEWCO ELECTRIC CO INC
41-3-S14-LN2-5006402OAKLAND INDUSTRIES LTDDBA E-T-A CIRCUIT BREAKERS
Technical Data | NSN 5925-01-208-6344
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 TAB W/SCREW
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BUSHING LENGTH0.250 INCHES NOMINAL
BODY LENGTH1.260 INCHES NOMINAL
BODY WIDTH0.730 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.900 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE2.560 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNS
NOMINAL THREAD SIZE0.375 INCHES
THREAD QUANTITY PER INCH27
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
STORAGE TYPEE ANY ACCEPTABLE