NSN 5925-01-209-9413

Part Details | CIRCUIT BREAKER

5925-01-209-9413 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: D78002, 3040115, 30401-15, 5925-01-209-9413, 01-209-9413, 5925012099413, 012099413

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 05, 198501-209-941300136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR DIMENSIONAL ENVELOPE

Cross Reference | NSN 5925-01-209-9413
Part Number Cage Code Manufacturer
D7800210988CNH INDUSTRIAL AMERICA LLC
30401-1513445COLE HERSEE COMPANY
Technical Data | NSN 5925-01-209-9413
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 QUICK DISCONNECT, MALE
RESET METHOD AUTOMATIC
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
OVERALL LENGTH32.25 MILLIMETERS NOMINAL
OVERALL HEIGHT19.81 MILLIMETERS NOMINAL
OVERALL WIDTH27.42 MILLIMETERS MAXIMUM
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED