Part Details | CIRCUIT BREAKER

5925-01-251-3454 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 5226721, 522672-1, JXD63B400, JJ63B400, JXD63B400, JJ63B400, JJ3B400, 5925-01-251-3454, 01-251-3454, 5925012513454, 012513454

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAR 18, 198701-251-345400136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-251-3454
Part Number Cage Code Manufacturer
522672-180020NAVAL AIR WARFARE CENTER AIRCRAFTDIVISION CODE 4.8.8.0.0.B BLDG 148-2
JXD63B40066842SIEMENS ENERGY AND AUTOMATION INCITE CIRCUIT PROTECTION DIV
JJ63B40066842SIEMENS ENERGY AND AUTOMATION INCITE CIRCUIT PROTECTION DIV
JXD63B40030086SPD ELECTRICAL SYSTEMS, INC
JJ63B40030086SPD ELECTRICAL SYSTEMS, INC
JJ3B40030086SPD ELECTRICAL SYSTEMS, INC
Technical Data | NSN 5925-01-251-3454
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 COMPRESSION
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH11.000 INCHES NOMINAL
BODY WIDTH7.484 INCHES NOMINAL
BODY HEIGHT4.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH9.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH9.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.500 INCHES NOMINAL
BOSS HEIGHT0.313 INCHES NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND VIBRATION RESISTANT AND SHOCK RESISTANT
SPECIAL FEATURESCIRCUIT BREAKER MUST BE COMPATIBLE WITH PANELBOARD NAEC PART NUMBER 625226-1
ARC QUENCHING METHOD AIR
STORAGE TYPEE ANY ACCEPTABLE
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED