NSN 5925-01-288-4245

Part Details | CIRCUIT BREAKER

5925-01-288-4245 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 247ASC2847002, 247AS-C2847-002, 23011114150211, 230-111-1-41-502-1-1, 20311163132, 203-111-6313-2, 5925-01-288-4245, 01-288-4245, 5925012884245, 012884245

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 06, 198801-288-424500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR DIMENSIONAL ENVELOPE

Cross Reference | NSN 5925-01-288-4245
Part Number Cage Code Manufacturer
247AS-C2847-00230003NAVAL AIR SYSTEMS COMMAND MANAGEDORIGINAL DESIGN ACTIVITY NOT
230-111-1-41-502-1-181541SENSATA TECHNOLOGIES MARYLAND, INC
203-111-6313-281541SENSATA TECHNOLOGIES MARYLAND, INC
Technical Data | NSN 5925-01-288-4245
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG
RESET METHOD MANUAL
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 CLIP
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH2.170 INCHES NOMINAL
OVERALL HEIGHT1.770 INCHES MAXIMUM
OVERALL WIDTH2.000 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED