NSN 5925-01-290-4804
Part Details | CIRCUIT BREAKER
5925-01-290-4804 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: QBHW3060HWFUNGUS PROOFING, QBHW3060HW/FUNGUS PROOFING, QBHW3060HF, 86423903, 8642390-3, 5925-01-290-4804, 01-290-4804, 5925012904804, 012904804
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 11, 1988 | 01-290-4804 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR DIMENSIONAL ENVELOPE

Cross Reference | NSN 5925-01-290-4804
Part Number | Cage Code | Manufacturer |
---|---|---|
QBHW3060HW/FUNGUS PROOFING | 89946 | EATON CORPORATION |
QBHW3060HF | 89946 | EATON CORPORATION |
8642390-3 | 98749 | SACRAMENTO AIR LOGISTICS CENTERSM-ALC/LIIL |
Technical Data | NSN 5925-01-290-4804
Characteristic | Specifications |
---|---|
POLE QUANTITY | 3 |
TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
RESET METHOD | MANUAL |
BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 6 CLIP |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
OVERALL LENGTH | 3.000 INCHES NOMINAL |
OVERALL HEIGHT | 2.375 INCHES NOMINAL |
OVERALL WIDTH | 2.875 INCHES NOMINAL |
MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT EACH POLE |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF AND MOISTURE RESISTANT |
STORAGE TYPE | E ANY ACCEPTABLE |
FRAGILITY FACTOR | MODERATELY RUGGED |