NSN 5925-01-292-2047

Part Details | CIRCUIT BREAKER

5925-01-292-2047 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: QBHW1025WFUNGUS PROOFING, QBHW1025W/FUNGUS PROOFING, 8642322, 5925-01-292-2047, 01-292-2047, 5925012922047, 012922047

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 12, 198901-292-204700136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR DIMENSIONAL ENVELOPE

Cross Reference | NSN 5925-01-292-2047
Part Number Cage Code Manufacturer
QBHW1025W/FUNGUS PROOFING89946EATON CORPORATION
864232298749SACRAMENTO AIR LOGISTICS CENTERSM-ALC/LIIL
Technical Data | NSN 5925-01-292-2047
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY1 COMPRESSION AND 1 CLIP
RESET METHOD MANUAL
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY1 CLIP AND 1 TERMINAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH2.375 INCHES NOMINAL
OVERALL HEIGHT1.000 INCHES NOMINAL
OVERALL WIDTH2.312 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS PROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED