NSN 5925-01-294-4583
Part Details | CIRCUIT BREAKER BOX
5925-01-294-4583 An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see SWITCH BOX; JACK BOX; TERMINAL BOX; and DISTRIBUTION BOX. For boxes designed to mount and protect but do not include circuit breakers, see CIRCUIT BREAKER BOX SUBASSEMBLY. See also INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; and CABINET, ELECTRICAL EQUIPMENT.
Alternate Parts: E2N12WED22M060, E2N12W/ED22M060, E22M060E2N12, E22M060/E2N12, 5925-01-294-4583, 01-294-4583, 5925012944583, 012944583
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | FEB 16, 1989 | 01-294-4583 | 19365 ( CIRCUIT BREAKER BOX ) |
REFERENCE DRAWINGS & PICTURES
4 POINT-RECTANGULAR

RECTANGULAR, FLUSH MOUNTING

Cross Reference | NSN 5925-01-294-4583
Part Number | Cage Code | Manufacturer |
---|---|---|
E2N12W/ED22M060 | 66842 | SIEMENS ENERGY AND AUTOMATION INCITE CIRCUIT PROTECTION DIV |
E22M060/E2N12 | 30086 | SPD ELECTRICAL SYSTEMS, INC |
Technical Data | NSN 5925-01-294-4583
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | RECTANGULAR, FLUSH MOUNTING |
OVERALL DEPTH | 5.062 INCHES NOMINAL |
OVERALL HEIGHT | 17.500 INCHES NOMINAL |
OVERALL WIDTH | 8.500 INCHES NOMINAL |
MATERIAL | STEEL |
ENTRANCE TYPE AND QUANTITY | 2 FIVE CONCENTRIC KNOCKOUT |
ENTRANCE DIAMETER NUMERIC DESIGNATOR | 0.250 |
MOUNTING METHOD | UNTHREADED HOLE |
STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.250 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 10.250 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
SYSTEM FOR WHICH DESIGNED | TWO WIRE SINGLE PHASE |
MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 100.0 |
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 240.0 |
MAIN LINE MAXIMUM DC VOLTAGE RATING IN VOLTS | 250.0 |
CIRCUIT BREAKER TYPE AND QUANTITY | 1 DOUBLE POLE |
CIRCUIT BREAKER CURRENT RATING IN AMPS | 60.0 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
FRAGILITY FACTOR | MODERATELY RUGGED |