NSN 5925-01-303-4802

Part Details | CIRCUIT BREAKER

5925-01-303-4802 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: X7928001, X-79280-01, QOU215, QOU215, 5925-01-303-4802, 01-303-4802, 5925013034802, 013034802

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 30, 198901-303-480200136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-303-4802
Part Number Cage Code Manufacturer
X-79280-0124658GENERAL REGULATOR CORP.DBA ACCUDRIV
QOU21556303SCHNEIDER ELECTRIC USA, INC.
QOU21556365SCHNEIDER ELECTRIC USA, INC.DBA SCHNEIDER ELECTRIC
Technical Data | NSN 5925-01-303-4802
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY2 COMPRESSION AND 2 CLIP
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL AND 2 CLIP
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH5.000 INCHES NOMINAL
BODY WIDTH1.500 INCHES NOMINAL
BODY HEIGHT2.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.340 INCHES NOMINAL
BOSS HEIGHT0.600 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED