NSN 5925-01-305-5196

Part Details | CIRCUIT BREAKER

5925-01-305-5196 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: UPG661REC56650291, UPG-66-1REC5-66-502-91, 5925-01-305-5196, 01-305-5196, 5925013055196, 013055196

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 07, 198901-305-519600136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-SINGLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-305-5196
Part Number Cage Code Manufacturer
UPG-66-1REC5-66-502-9181541SENSATA TECHNOLOGIES MARYLAND, INC
Technical Data | NSN 5925-01-305-5196
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY4 TAB, SOLDER LUG
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM
BODY WIDTH1.515 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.499 INCHES MINIMUM AND 1.561 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.629 INCHES MINIMUM AND 1.691 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BOSS HEIGHT0.099 INCHES MINIMUM AND 0.161 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE2.000 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC
SWITCH TERMINAL TYPE QUICK DISCONNECT, MALE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND SALT SPRAY PROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED