NSN 5925-01-307-7078

Part Details | CIRCUIT BREAKER

5925-01-307-7078 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: UPL1111REC2241403M, UPL-111-1REC22-41-403-M, 5925-01-307-7078, 01-307-7078, 5925013077078, 013077078

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59SEP 16, 198901-307-707800136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

Cross Reference | NSN 5925-01-307-7078
Part Number Cage Code Manufacturer
UPL-111-1REC22-41-403-M81541SENSATA TECHNOLOGIES MARYLAND, INC
Technical Data | NSN 5925-01-307-7078
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 THREADED STUD
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY WIDTH2.265 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
BOSS HEIGHT0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE2.655 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT DOUBLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 3.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 50.0 DC
SWITCH TERMINAL TYPE TAB, SOLDER LUG
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED