NSN 5925-01-311-3079

Part Details | CIRCUIT BREAKER

5925-01-311-3079 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: BQ2C050, BQ2-C050, 5925-01-311-3079, 01-311-3079, 5925013113079, 013113079

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 23, 198901-311-307900136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR DIMENSIONAL ENVELOPE

Cross Reference | NSN 5925-01-311-3079
Part Number Cage Code Manufacturer
BQ2-C05021810CHALLENGER ELECTRICAL EQUIPMENT CORP
Technical Data | NSN 5925-01-311-3079
Characteristic Specifications
POLE QUANTITY2
TERMINAL TYPE AND QUANTITY2 CLIP AND 2 TAB W/SCREW
RESET METHOD MANUAL
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH3.060 INCHES NOMINAL
OVERALL HEIGHT2.000 INCHES NOMINAL
OVERALL WIDTH2.960 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
STORAGE TYPEE ANY ACCEPTABLE
SPECIAL HANDLING FEATURE MAGNETIC
FRAGILITY FACTOR MODERATELY RUGGED