NSN 5925-01-316-3065
Part Details | CIRCUIT BREAKER BOX
5925-01-316-3065 An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see SWITCH BOX; JACK BOX; TERMINAL BOX; and DISTRIBUTION BOX. For boxes designed to mount and protect but do not include circuit breakers, see CIRCUIT BREAKER BOX SUBASSEMBLY. See also INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; and CABINET, ELECTRICAL EQUIPMENT.
Alternate Parts: Q02RB, QO2L40RB, QO2L40RB, 5925-01-316-3065, 01-316-3065, 5925013163065, 013163065
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 08, 1990 | 01-316-3065 | 19365 ( CIRCUIT BREAKER BOX ) |
REFERENCE DRAWINGS & PICTURES
4 POINT-RECTANGULAR
RECTANGULAR, SURFACE MOUNTING
Cross Reference | NSN 5925-01-316-3065
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| Q02RB | 56365 | SCHNEIDER ELECTRIC USA, INC.DBA SCHNEIDER ELECTRIC |
| QO2L40RB | 56365 | SCHNEIDER ELECTRIC USA, INC.DBA SCHNEIDER ELECTRIC |
| QO2L40RB | 14280 | SCHNEIDER ELECTRIC USA, INC.DBA SCHNEIDER ELECTRIC |
Technical Data | NSN 5925-01-316-3065
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | RECTANGULAR, SURFACE MOUNTING |
| OVERALL DEPTH | 3.190 INCHES NOMINAL |
| OVERALL HEIGHT | 9.180 INCHES NOMINAL |
| OVERALL WIDTH | 4.810 INCHES NOMINAL |
| MATERIAL | STEEL |
| ENTRANCE TYPE AND QUANTITY | 8 SINGLE KNOCKOUT |
| CABLE ENTRANCE DIAMETER | 0.500 INCHES NOMINAL |
| MOUNTING METHOD | UNTHREADED HOLE |
| STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.500 INCHES NOMINAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
| SYSTEM FOR WHICH DESIGNED | THREE WIRE SINGLE PHASE |
| MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 40.0 |
| MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 240.0 |
| CIRCUIT BREAKER TYPE AND QUANTITY | 2 SINGLE POLE |
| SPECIAL FEATURES | ITEM IS RAINPROOF AND UL LISTED |