NSN 5925-01-330-5275

Part Details | CIRCUIT BREAKER

5925-01-330-5275 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 26123252, 2612325-2, 2293212462, 229-3-21246-2, 5925-01-330-5275, 01-330-5275, 5925013305275, 013305275

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 05, 199001-330-527500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

MULTIPOLE-MULTIPLE ACTUATOR TYPE

Cross Reference | NSN 5925-01-330-5275
Part Number Cage Code Manufacturer
2612325-206424ALLIANT TECHSYSTEMS OPERATIONS LLCDIV DEFENSE ELECTRONIC SYSTEMS
229-3-21246-281541SENSATA TECHNOLOGIES MARYLAND, INC
Technical Data | NSN 5925-01-330-5275
Characteristic Specifications
POLE QUANTITY3
TERMINAL TYPE AND QUANTITY6 THREADED STUD
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH5.115 INCHES MINIMUM AND 5.135 INCHES MAXIMUM
BODY WIDTH3.108 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.540 INCHES MINIMUM AND 3.560 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM
BOSS HEIGHT0.210 INCHES MINIMUM AND 0.230 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE3.540 INCHES MINIMUM AND 3.560 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 3.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 50.0 DC
SWITCH TERMINAL TYPE TAB, SOLDER LUG
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED