NSN 5930-00-045-4390
Part Details | THERMOSTATIC SWITCH
5930-00-045-4390 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 3100622, 3100-6-22, 11731120, 5930-00-045-4390, 00-045-4390, 5930000454390, 000454390
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | MAY 09, 1967 | 00-045-4390 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-045-4390
Part Number | Cage Code | Manufacturer |
---|---|---|
3100-6-22 | 14604 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
11731120 | 19200 | US ARMY ARDEC RDECOM |
Technical Data | NSN 5930-00-045-4390
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 9 CYLINDRICAL W/FLANGE |
OVERALL HEIGHT | 0.603 INCHES NOMINAL |
BODY HEIGHT | 0.305 INCHES NOMINAL |
OVERALL DIAMETER | 0.650 INCHES MINIMUM AND 0.670 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF180.00 ACTUATION POINT NOMINAL AND AF165.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | FLANGE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL |
MOUNTING FACILITY CIRCLE RADIUS | 0.660 INCHES NOMINAL |
TEST DATA DOCUMENT | 81349-MIL-E-5272 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIAL TEST FEATURES | 100000 MIN OPERATING CYCLES |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND FIRE RESISTANT AND HUMIDITY RESISTANT AND MOISTURE PROOF AND SALT SPRAY PROOF AND SUBMERSIBLE |