NSN 5985-00-105-3697
Part Details | ELECTRICAL DUMMY LOAD
5985-00-105-3697 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.
Alternate Parts: 25155701, 2515570-1, LCH5, LCH5, LCH5, 91757, 5985-00-105-3697, 00-105-3697, 5985001053697, 001053697
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUL 01, 1968 | 00-105-3697 | 00335 ( DUMMY LOAD, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-00-105-3697
Part Number | Cage Code | Manufacturer |
---|---|---|
2515570-1 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
LCH5 | 54X10 | RAYTHEON COMPANYDBA RAYTHEON |
LCH5 | 49956 | RAYTHEON COMPANYDBA RAYTHEON |
LCH5 | 3B150 | RAYTHEON COMPANYDBA RAYTHEON |
91757 | 21845 | SOLITRON DEVICES, INC. |
Technical Data | NSN 5985-00-105-3697
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
OVERALL LENGTH | 9.500 INCHES NOMINAL |
OVERALL WIDTH | 4.473 INCHES MINIMUM AND 4.713 INCHES MAXIMUM |
BODY DIAMETER | 3.940 INCHES MAXIMUM |
POWER RATING | 70.000 KILOWATTS PEAK AND 2.500 KILOWATTS AVERAGE |
VOLTAGE STANDING WAVE RATIO | 1.10 |
TERMINATION TYPE | WAVEGUIDE FLANGE |
WAVEGUIDE FLANGE DESIGNATION | UG149A/U |
COOLING METHOD | FORCED LIQUID |
COOLANT CHAMBER PRESSURE | 150.0 POUNDS PER SQUARE INCH GAGE |
INPUT COOLANT TEMP | 45.0 DEG CELSIUS |
COOLING SYSTEM COOLANT FLOW RATE | 0.7 GALLONS PER MINUTE |
OPERATING POSITION | ALL POSITIONS |
FRAGILITY FACTOR | MODERATELY RUGGED |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |